  • Conforms to IEC Standards 60309-1 and 60309-2 Watertight: IP67 per IEC 529 Splashproof: IP54 per IEC 529
  • Flame Class Rating per UL94: VO for Contact Carriers (insulators) HB or better for Housings (UV Stabilized)
  • Impact Resistance: Units conditioned to -25°C for 6 hours and dropped 8 times from 30"
  • Crush: Units conditioned to -25°C for 6 hours and 250 Ibs. of force applied for 1 minute.
  • Cable Grip Retention: (applied to min. cable size)
    Unit

    20A
    30A
    60A
    100A
    Force, Ibs.
    30
    75
    150
    150
    Torque, ft. Ibs.
    0.4
    0.5
    1.0
    1.0


  • Electrical
    Dielectric Voltage: 3000V maximum
    Maximum Working Voltage: 600 RMS
    Current Interrupting:
    Certified at full-rated current and voltage
    Temperature Rise:
    Maximum 30°C temperature at full rated current
    Overload:
    50 cycles at 150% of rated current and
    100% of rated voltage. (Power factor at .75-.80)
    Endurance with Load: (at .75-.80 Power Factor)
    20A- 5,000 mated cycles at full-rated current/voltage.
    30A and 60A- 2,000 mated cycles with full-rated current/voltage applied on every other cycle.
    100A- 500 mated cycles with full-rated current/voltage applied on every other cycle.